Find great deals for G Agilent / HP B Sweep Oscillator. Shop with confidence on eBay!. Find great deals for HP b Sweep Oscillator With b RF Plug-in. Shop with confidence on eBay!. This manual may contain references to HP or Hewlett-Packard. Please note that B Sweep Oscillator Operating and Service Manual.

Author: Yozshuzil Kazranris
Country: Netherlands
Language: English (Spanish)
Genre: Health and Food
Published (Last): 13 December 2012
Pages: 493
PDF File Size: 11.8 Mb
ePub File Size: 6.35 Mb
ISBN: 119-7-81662-981-8
Downloads: 57950
Price: Free* [*Free Regsitration Required]
Uploader: Dourg

Once the sweeper has been set for a particular measurement, all front panel settings HP and HP series plug-in can be Saved and later Recalled to repeat the measurement by accessing one of nine internal storage registers.

These markers, combined with the high resolution digital readout, make the accurate location of important frequency responses easy. Nonvolatile memory is included so that all memories are retained even when line power is removed. You can also use marker sweep to zoom in on a particular frequency span while retaining your original sweep limits.

HP Agilent Keysight, B + A

It incorporates the efficiency of microprocessor control with state-of-the-art YIG-tuned oscillators and GaAs FET amplifiers to produce a high performance sweep oscillator system ideally suited for either manual or automatic measurements. All front panel controls except the ac line switch may be programmed or controlled via the HP-IB.

Power level control is calibrated with 0. Yp self test is performed at turn on or whenever the instrument preset function is activated. With the HP all front panel functions, e.

If there is a problem, error codes are displayed hhp the front panel to help locate the problem quickly to the board and component level. In addition, it is compatible with HP network analyzers, counters, noise figure meters, power meters, and microwave link analyzers to provide complete solutions.

  HALOXYLON SALICORNICUM PDF

B Sweep Oscillator Mainframe [Obsolete] | Keysight (formerly Agilent’s Electronic Measurement)

HP has been designed to include many features that not only speed up and simplify measurements but also improve accuracy. The HP series area a particularly attractive plug-in choice when economical single-band operation is desired with the HP mainframe.

The active marker frequency or the difference frequency between 8350n two markers is read easily from high resolution digital display. And the HP B is directly compatible with such measurement systems as the A scalar network analyzers. This function verifies that the HP B is functioning properly. This means there are no limitations in designing your own customized test systems. Please call for availability. Calibrated power sweeps are available for characterizing 83350b performance as a function of power.

The output from this function may be processed through a network analyzer such as the HP A or the HP A and viewed on a two channel display.

HP 8350b Sweep Oscillator With 83592b RF Plug-in

HP System HP is a powerful general-purpose for swept microwave measurements, wideband CW signal generation and automatic testing. View Cart My Account. Simply combining the HP series plug-in including the one you may already own with an HP A Adapter makes all the convenient digital controls, markers, and HP-IB capability of the HP immediately available to you. A key marker feature, marker D, computes the difference between any two markers.

Utilizing the Learn Mode function, the HP becomes a “talker” as well as “listener” on the bus, transferring all manually entered front panel controls to the computer. You can easily configure a source to meet your application’s frequency coverage and power requirements. This feature supplies nine memory locations, each storing a complete front panel set-up. Five markers are available with the HP B. Slope and internal leveling controls are standard on all units.

The millimeter-wave bands are covered by the HP series millimeter-wave source modules, frequency multipliers that provide coverage in the Function values are easily modified using the appropriate knob, step keys, or data entry keyboard. This means your automatic 8350bb systems can now characterize a device both as a function of frequency and input power level.

  JOSE LUIS BUSANICHE HISTORIA ARGENTINA PDF

HP Mainframe HP has been designed to include many features that not only speed up and simplify measurements but also improve accuracy.

HP is a powerful general-purpose for swept microwave measurements, wideband CW signal generation and automatic testing.

Sweep Oscillator applications are greatly enhanced by the features of the HP B. The 18 GHz to Frequency accuracy at 18 GHz is 20 MHz, exceeding that available on most single-band plug-ins.

Providing the finest test equipment solutions since 1992

Hewlett Packard B Shown. All function values sweep limit frequencies, marker frequencies, etc. Just combine the versatile HP mainframe with any of the 32 standard RF plug-ins and you are ready to make measurements.

Five independent, continuously variable markers are available to note your measurement frequencies. For measurements with HP Microwave Link Analyzers, specially characterized HP series plug-ins can be used with the HP to create an up converter for communications distortion measurements. The HP B makes “simultaneous” comparison of two separate frequency ranges or power levels easy via the alternate sweep mode.

The HP series plug-ins offer output power level control previously unavailable on a swept source. When the alternate sweep mode is activated, the HP B alternates between the current front panel setting and any stored memory setting on successive sweeps.

The HP B has three methods of changing function values: